CSF 15-18 BMW M2 (F87) Race-Spec Oil Cooler
Talk to an expert
Need help? Check fitment, get personalized recommendations and tips.
- Product description
-
BMW M drivers demand nothing but the best from and for their vehicles. While the F87 M2 (N55) is very capable on the street and track, it does suffer from heat issues in extreme conditions. Extensive track testing reveals the engine oil temps reaching upwards of 280? which will send the M2 into limp mode. The CSF Oil Cooler has been track tested in 103? (115 ? Heat Index) and keep the oil temps much lower than factory with a maximum temperature recorded at 240? throughout testing. The extra cooling performance is accomplished in a design that is a true ""drop-in fit"" requiring no modifications to install. It accepts all attaching oem components including oil-line connections, mounting brackets and shroud/ducting. This is accomplished by utilizing CSF's AC Condenser Technology with a 1-Row super-high pressure 26mm multi-channel microtube. The front full-size core has 17 cooling tubes vs. oem 15 tubes while the backside cooler has an additional 6 rows. This also increases the overall oil volume of the system by 0.5 quarts (0.47 liters). Product video
Technical specification
Article nr: csf8104Manufacture Partnumber: 8104 - Suitable for
- BMW F87 M2
- Brand
-
CSF manufactures the most efficient and advanced cell packs for coolers in the entire industry. It is a status gained through its innovative Tube & Fin-Technology and market-leading tests in terms of cooling and flow. These technologies have made it possible for CSF to develop cooler technology throughout the market.
B-Tube Technology
Normally, O-shaped fluid channels are used. CSF, on the other hand, uses channels shaped like a B. These B-shaped tubes are very carefully shaped and then soldered together at the seam. This allows the CSF to use a thinner and lighter aluminum (which gives a better cooling effect) because the shaping makes the material stronger than when using the traditional O-shape.
This type of design on the channels increases the surface where the heat exchanges occur with approx. 15% compared to the old technology!
Highly efficient flanges
CSF uses flanges with several ventilations that are carefully lined up to maximize airflow through the cell pack. Each model of cooler is special and each specification is carefully measured and calculated and then tested in CSF's wind tunnel for the best possible cooling effect.
- Accessories & Spare Parts
- Guarantee
-